Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Arq. bras. cardiol ; 107(6): 568-575, Dec. 2016. tab, graf
Article in English | LILACS | ID: biblio-838668

ABSTRACT

Abstract Background: Cardioinhibitory vasovagal response is uncommon during the tilt test (TT). Heart rate variability (HRV) by use of spectral analysis can distinguish patients with that response. Objective: To compare the HRV in patients with cardioinhibitory vasovagal syncope (case group - G1) with that in patients without syncope and with negative response to TT (control group - G2). Methods: 64 patients were evaluated (mean age, 36.2 years; 35 men) and submitted to TT at 70 degrees, under digital Holter monitoring. The groups were paired for age and sex (G1, 40 patients; G2, 24). Results: In G1, 21 patients had a type 2A response and 19 had type 2B, with mean TT duration of 20.4 minutes. There was a greater low frequency (LF) component (11,6 versus 4,5 ms2, p=0.001) and a lower low/high frequency ratio in the supine position (3,9 versus 4,5 ms2, p=0.008) in G1, with no difference during TT between the groups. Applying the receiver operating characteristic curve for cardioinhibitory response, the area under the curve was 0.74 for the LF component in the supine position (p = 0.001). The following were observed for the cutoff point of 0.35 ms(2) for the LF component: sensitivity, 97.4%; specificity, 83.3%; positive predictive value, 85.3%; negative predictive value, 96.9%; and positive likelihood ratio, 5.8. Conclusion: HRV in the supine position allowed identifying patients with syncope and cardioinhibitory response with a high negative predictive value and likelihood ratio of 5.8.


Resumo Fundamento: A resposta cardioinibitória vasovagal ao teste de inclinação (TI) é pouco frequente. A variabilidade da frequência cardíaca (VFC) por meio da análise espectral pode discernir os pacientes (pts) com aquela resposta. Objetivo: Avaliar a VFC em pts com síncope vasovagal cardioinibitória (grupo caso - G1), comparando-a com a VFC de pts sem síncope e com resposta negativa ao TI (grupo controle - G2). Métodos: foram avaliados 64 pts, média de idade 36,2 anos, 35 homens, submetidos ao TI a 70º, sob monitoramento pelo Holter digital. Os grupos foram pareados por idade e sexo, sendo 40 pts do G1 e 24 do G2. Resultados: No G1, 21 pts apresentaram resposta tipo 2A e 19, tipo 2B, com média do TI de 20,4 min. Houve maior valor do componente de baixa frequência (BF) (11,6 versus 4,5 ms2, p=0,001) e menor relação baixa/alta frequência na posição supina (3,9 versus 4,5 ms2, p=0,008) no G1, sem diferença durante o TI. Aplicando-se a curva de operação característica para resposta cardioinibitória, foi obtida a área abaixo da curva de 0,74 para o componente BF na posição supina (p=0,001). Para o ponto de corte de 0,35 ms2 para BF observaram-se: sensibilidade, 97,4%; especificidade, 83,3%; valor preditivo positivo, 85,3%; valor preditivo negativo, 96,9%; e razão de probabilidade positiva, 5,8. Conclusão: A VFC na posição supina permitiu identificar os pts com síncope e com resposta cardioinibitória, com um alto valor preditivo negativo e uma razão de probabilidade de 5,8.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Young Adult , Tilt-Table Test/methods , Syncope, Vasovagal/physiopathology , Heart Rate/physiology , Reference Values , Time Factors , Blood Pressure/physiology , Prospective Studies , ROC Curve , Electrocardiography, Ambulatory , Supine Position/physiology , Statistics, Nonparametric , Electrocardiography/methods
2.
Rev. bras. cir. cardiovasc ; 13(3): 263-8, jul.-set. 1998. ilus, tab
Article in Portuguese | LILACS | ID: lil-223590

ABSTRACT

Objetivo: O objetivo deste estudo é avaliar o desempenho do marcapasso VDD com eletrodo único Dromos-Biotronic. Casuística e Métodos: Num período de 12 meses foram realizados 21 implantes de sistemas VDD com eletrodo único, no Instituto do Coraçao do Hospital Madre Teresa. Onze pacientes eram do sexo feminino, a média de idades foi de 59,8 anos (16 a 77). Todos os pacientes apresentavam bloqueio atrioventricular (BAV) avançado (BAV total e BAV segundo grau). A miocardiopatia chagásica foi a etiologia de maior prevalência (76,1 por cento), seguido de pós-cirúrgico (14,3 por cento), miocardioesclerose (4,7 por cento) e de etiologia desconhecida (4,7 por cento). Os pacientes utilizaram eletrodo SL 60-/13-UP Biotronic. A técnica de implante foi a tradicional para implantes VVI endocavitários, apenas com o cuidado de posicionar os anéis de "sensing" atrial em posiçao alta ou médio-alta no átrio e medir os potenciais desta cavidade. A avaliaçao pós-operatória foi realizada a nível ambulatorial, no terceiro mês de pós-operatório, constando de análise telemétrica, ecocardiográfica e teste de esforço em esteira, para avaliaçao da funçao ventricular, tolerância ao exercício e manutençao do sincronismo AV no repouso e durante movimento. Resultados: A análise telemétrica demonstrou boa captura atrial no repouso em todos os pacientes (100 por cento). O teste de limiar de sensibilidade atrial revelou onda "P" média de 1,27 mV, sendo que apenas um paciente tinha sensibilidade atrial reprogramada para 0,1 mV devido a perda de captura dependente de posiçao; os demais pacientes foram mantidos com programaçao à nominal deste parâmetro (0,2 mV). A ecocardiografia revelou melhora da fraçao de ejeçao em 71,4 por cento dos pacientes e 90,47 por cento relataram melhora funcional (NYHA). Ao teste de esforço 95,23 por cento dos pacientes mantiveram o sincronismo AV no pico do esforço. Conclusao: A estimulaçao cardíaca artificial em VDD com eletrodo único demonstrou excelente alternativa à estimulaçao em DDD, porque manteve o sincronismo AV em repouso e no exercício, melhorou o desempenho hemodinâmico e, conseqüentemente, a classe funcional da maioria dos pacientes, sem a necessidade de se utilizar um segundo eletrodo, evitando, assim, as complicaçoes de implante e seu acompanhamento deste. Desta forma, o sistema VDD com eletrodo único reúne as facilidades de implante dos sistemas VVI, com os benefícios hemodinâmicos dos sistemas DDD...


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Heart Block/therapy , Cardiac Pacing, Artificial , Pacemaker, Artificial
SELECTION OF CITATIONS
SEARCH DETAIL